DocumentCode :
1741246
Title :
Respiratory gating of sliding window IMRT
Author :
Yorke, Ellen ; Mageras, Gig ; LoSasso, Thomas ; Mostafavi, Hassan ; Ling, Clifton
Author_Institution :
Dept. of Med. Phys., Memorial Sloan-Kettering Cancer Center, New York, NY, USA
Volume :
3
fYear :
2000
fDate :
2000
Firstpage :
2118
Abstract :
Breathing motion may limit sites of applicability for intensity modulated radiation therapy (IMRT). Respiratory gating reduces motion by activating the beam during a chosen phase of respiration. We investigated the effect of gating on the dose distribution of sliding window dynamic multileaf collimator (DMLC) fields. A Varian 2100C beam was gated by the Varian real time position management system that tracks moving infrared reflective markers with a wall-mounted camera. A rotating eccentric wheel simulated marker breathing motion. Dose distributions from normal (ungated) and gated DMLC fields were compared using film dosimetry and also by calculating dose distributions from the leaf motion log files. Fields included prostate (15 MV) and H&N (6 MV) treatment fields and special test fields. Kodak V films under polystyrene phantom were exposed separately for gated and ungated operation. Additional ungated fields were filmed as controls. Log files for gated and ungated deliveries were copied to a program written in-house which uses the clinical treatment planning system to calculate the dose distribution delivered by the recorded leaf motion. The films were digitized, optical densities converted to dose, and matched pairs of films were registered. The largest differences (≈5% or ~1 mm) occurred in high dose gradient regions and were consistent with uncertainties in aligning pairs of films. Gated vs. ungated dose distributions calculated from the fog files agreed to better than 0.5%. These preliminary results show no deleterious effects of gating on DMLC dose distributions
Keywords :
dosimetry; medical image processing; pneumodynamics; radiation therapy; 15 MV; 6 MV; Varian real time position management system; breathing motion; clinical treatment planning system; dose distribution; film dosimetry; head and neck treatment fields; high dose gradient regions; intensity modulated radiation therapy; moving infrared reflective markers; polystyrene phantom; prostate treatment fields; respiratory gating; rotating eccentric wheel; sliding window IMRT; sliding window dynamic multileaf collimator fields; Biomedical applications of radiation; Cameras; Collimators; Dosimetry; Imaging phantoms; Intensity modulation; Optical films; Real time systems; Testing; Wheels;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2000. Proceedings of the 22nd Annual International Conference of the IEEE
Conference_Location :
Chicago, IL
ISSN :
1094-687X
Print_ISBN :
0-7803-6465-1
Type :
conf
DOI :
10.1109/IEMBS.2000.900547
Filename :
900547
Link To Document :