• DocumentCode
    1753831
  • Title

    Traveling-Wave Starting Algorithm Based on Least Square Method

  • Author

    He, Renwang ; Teng, Jinfen

  • Author_Institution
    Sch. of Electr. & Electron. Eng., East China Jiaotong Univ., Nanchang, China
  • fYear
    2011
  • fDate
    25-28 March 2011
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    The paper proposes a new method of fault transient signal singularity detection by wavelet transform, analyzes the main drawbacks of present starting algorithms which use only adjacent scale of WTMM of WTMS ratio to determine the Lipschitz coefficients, presents a new method for estimating Lipschitz coefficients based on least square method by fitting the data of various scales. ATP-EMTP simulation results show that the proposed algorithm can more accurately analyze singularity of fault signal.
  • Keywords
    fault diagnosis; least mean squares methods; power system faults; power system transients; signal detection; wavelet transforms; ATP-EMTP simulation; Lipschitz coefficient estimation; fault transient signal singularity detection; least square method; traveling-wave starting algorithm; wavelet transform; Least squares methods; Power transmission lines; Transient analysis; Wavelet analysis; Wavelet transforms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference (APPEEC), 2011 Asia-Pacific
  • Conference_Location
    Wuhan
  • ISSN
    2157-4839
  • Print_ISBN
    978-1-4244-6253-7
  • Type

    conf

  • DOI
    10.1109/APPEEC.2011.5748912
  • Filename