Sensorless power factor control for mixed conduction mode boost converter using passivity-based control
Author
Cimini, Gionata ; Ippoliti, Gianluca ; Orlando, Giuseppe ; Pirro, Matteo
Author_Institution
Dipt. di Ing. dell´Inf., Univ. Politec. delle Marche, Ancona, Italy
Volume
7
Issue
12
fYear
2014
fDate
12 2014
Firstpage
2988
Lastpage
2995
Abstract
In this study, a power factor (PF) control for an AC-DC boost converter operating in light load condition has been presented. A passivity-based current control able to operate in either continuous conduction mode (CCM) and in discontinuous conduction mode has been implemented. A voltage proportional integral-based control with input feed-forward has been implemented in order to increase PF and regulate the DC output. A current observer, suitable for both operating modes has been adopted in order to eliminate the need for expensive current sensor. The proposed mixed conduction mode control scheme has been numerically tested using a powerful software simulation platform and compared with classical CCM control scheme. Experimental tests have been finally performed on a real boost converter controlled by a Texas Instruments microcontroller in order to validate the results and to prove the feasibility of the algorithm.
Keywords
AC-DC power convertors; electric current control; feedforward; power control; power factor; AC-DC boost converter; CCM control scheme; DC output; Texas Instruments microcontroller; continuous conduction mode; current control; input feed-forward; light load condition; mixed conduction mode boost converter; mixed conduction mode control scheme; passivity-based control; powerful software simulation platform; sensorless power factor control; voltage proportional integral-based control;
fLanguage
English
Journal_Title
Power Electronics, IET
Publisher
iet
ISSN
1755-4535
Type
jour
DOI
10.1049/iet-pel.2013.0967
Filename
6983704
Link To Document