Title :
A cMUT probe for ultrasound-guided focused ultrasound targeted therapy
Author :
Gross, Dominique ; Coutier, Caroline ; Legros, Mathieu ; Bouakaz, Ayache ; Certon, Dominique
Author_Institution :
Groupe de Rech. en Mater., Microelectron., Acoust. et Nanotechnol. (GREMAN), Francois-Rabelais Univ., Tours, France
Abstract :
Ultrasound-mediated targeted therapy represents a promising strategy in the arsenal of modern therapy. Capacitive micromachined ultrasonic transducer (cMUT) technology could overcome some difficulties encountered by traditional piezoelectric transducers. In this study, we report on the design, fabrication, and characterization of an ultrasound-guided focused ultrasound (USgFUS) cMUT probe dedicated to preclinical evaluation of targeted therapy (hyperthermia, thermosensitive liposomes activation, and sonoporation) at low frequency (1 MHz) with simultaneous ultrasonic imaging and guidance (15 to 20 MHz). The probe embeds two types of cMUT arrays to perform the modalities of targeted therapy and imaging respectively. The wafer-bonding process flow employed for the manufacturing of the cMUTs is reported. One of its main features is the possibility of implementing two different gap heights on the same wafer. All the design and characterization steps of the devices are described and discussed, starting from the array design up to the first in vitro measurements: optical (microscopy) and electrical (impedance) measurements, arrays´ electroacoustic responses, focused pressure field mapping (maximum peak-to-peak pressure = 2.5 MPa), and the first B-scan image of a wire-target phantom.
Keywords :
acoustoelectric effects; acoustoelectric transducers; biomedical transducers; biomedical ultrasonics; capacitive transducers; electric impedance measurement; hyperthermia; micromachining; optical microscopy; phantoms; ultrasonic therapy; ultrasonic transducer arrays; wafer bonding; B-scan image; array electroacoustic responses; cMUT arrays; cMUT probe; capacitive micromachined ultrasonic transducer; electrical impedance measurements; focused pressure field mapping; frequency 1 MHz; frequency 15 MHz to 20 MHz; gap heights; hyperthermia; in vitro measurements; optical microscopy; sonoporation; thermosensitive liposome activation; ultrasonic imaging; ultrasound-guided focused ultrasound targeted therapy; wafer-bonding process flow; wire-target phantom; Acoustics; Fabrication; Imaging; Medical treatment; Probes; Transducers; Ultrasonic imaging;
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
DOI :