    Characteristics and Accuracy of a Fully Corrected Four-port Vector Network Analyzer

  • Author

    Schindler, M. ; Phillips, P. ; Fennelly, M. ; Adamian, V. ; Enquist, P.

  • Author_Institution
    ATN Microwave, 85 Rangeway Road, North Billerica, MA 01862, www.atn-microwave.com
  • Volume
    32
  • fYear
    1997
  • fDate
    Dec. 1997
  • Firstpage
    127
  • Lastpage
    130
  • Abstract
    A new, fully corrected, four ports-parameter test system has been developed and evaluated. In this system, all sixteen s-parameters are accurately measured by a fully vector corrected system. The new test system is compared to conventional methods of measuring 4-port s-parameters, and measurement examples are shown. Accuracy of measurements with the new system is compared to measurements made conventionally. The importance of minimizing cross-talk between ports in the new test set is described, and the high level of performance achieved with the system is defined.
  • Keywords
    Calibration; Circulators; Couplers; Distortion measurement; Microwave devices; Microwave technology; Round robin; Scattering parameters; Switches; System testing;