DocumentCode :
184579
Title :
Cardiac output measured by electrical impedance tomography: Applications and limitations
Author :
Proenca, M. ; Rapin, M. ; Braun, F. ; Sola, J. ; Lemay, M. ; Thiran, J.-P.
Author_Institution :
Syst. Div., Swiss Center for Electron. & Microtechnol. (CSEM), Neuchatel, Switzerland
fYear :
2014
fDate :
22-24 Oct. 2014
Firstpage :
236
Lastpage :
239
Abstract :
Cardiac output is one of the most determining parameters to assess cardiac function and manage hemodynamically unstable patients. Its continuous and non-invasive estimation, however, remains a technical challenge. In that context, electrical impedance tomography (EIT), an emerging modality for a new class of safe and portable hemodynamic monitors, appears as an appealing candidate for the continuous monitoring of cardiac output. However, the interpretation of EIT signals requires a feasibility study to be carried out. In the context of the Nano-Tera ObeSense project, we thus proposed a model and numerical simulations to evaluate the impact of myocardial motion in the estimation of cardiac output by EIT. It was found that 64% of the cardiac EIT signal originates from the mechanical interaction of the heart muscle with its surrounding tissues. However, because these movements are correlated with ventricular blood volume, the EIT-based estimation of cardiac output is not compromised. In parallel, regarding the technical aspect of EIT, we proposed innovative solutions for its measurement setup where the wiring complexity is drastically reduced, thus opening the way towards portable EIT systems.
Keywords :
bioelectric phenomena; biomedical measurement; blood; cardiology; electric impedance imaging; haemodynamics; muscle; numerical analysis; EIT-based estimation; NanoTera ObeSense project; biological tissues; cardiac EIT signal; cardiac function; cardiac output estimation; cardiac output measurement; electrical impedance tomography; heart muscle; hemodynamically unstable patients; mechanical interaction; myocardial motion; numerical simulations; portable EIT systems; portable hemodynamic monitors; ventricular blood volume; wiring complexity; Biomedical monitoring; Estimation; Heart; Impedance; Monitoring; Sensors; Tomography; EIT; bio-impedance; bio-potential; cardiac output; electrical impedance tomography; stroke volume; wearable sensor;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Circuits and Systems Conference (BioCAS), 2014 IEEE
Conference_Location :
Lausanne
Type :
conf
DOI :
10.1109/BioCAS.2014.6981706
Filename :
6981706
Link To Document :
بازگشت