DocumentCode :
1862427
Title :
Single-Phase Active Rectifier Selection for Fault Tolerant Machine
Author :
AbdEl-hafez, A.A. ; Cross, Andrew M. ; Forsyth, A.J. ; Trainer, D.R. ; Cullen, J.A.
Author_Institution :
School of Electrical and Electronic Engineering, Manchester University, PO Box 88, Manchester, M60 1QD, UK, a-el-hafez@postgrad.manchester.ac.uk, Fax +44(0)161 306 4774
fYear :
2006
fDate :
4-6 April 2006
Firstpage :
435
Lastpage :
439
Abstract :
A fault tolerant, 5-phase PM generator has been developed for use on the low pressure (LP) shaft of an aircraft gas turbine engine. The machine operates at variable speed and therefore has a variable voltage, variable frequency electrical output (VVVF). The generator is to be used to provide a 350V DC bus for distribution throughout the aircraft, and a study has been carried out that identifies the most suitable AC-DC converter topology for this machine in terms of losses, electrical component ratings, filtering requirements and circuit complexity.
Keywords :
AC-DC Converter; Fault Tolerant; More Electric Aircraft; PM Machine; Variable Speed;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Power Electronics, Machines and Drives, 2006. The 3rd IET International Conference on
Conference_Location :
The Contarf Castle, Dublin, Ireland
Print_ISBN :
0-86341-609-8
Type :
conf
Filename :
4123560
Link To Document :
بازگشت