DocumentCode :
1871564
Title :
Three phase pipe flow imaging using a capacitance tomography system
Author :
Isaksen, Ø
Author_Institution :
Christian Michelsen Res., Fantoft Bergen, Norway
fYear :
1996
fDate :
35173
Firstpage :
42675
Lastpage :
42680
Abstract :
Several tomography systems for pipe flow imaging have been developed which are based on capacitance sensors measuring the permittivity of the flowing components. Several reconstruction techniques for reconstructing the measured capacitances has been developed. The most commonly used reconstruction algorithm is called the linear backprojection (LBP) algorithm and represents a fast and fairly crude algorithm. In this paper it is shown that in using the LBP-algorithm one must be very careful in interpreting the results. Methods for using a capacitance tomography system based an the LBP-algorithm for three phase oil/water/gas pipe flow imaging is outlined and preliminary results are presented
Keywords :
capacitance measurement; computerised tomography; flow visualisation; image reconstruction; image sensors; multiphase flow; physics computing; pipe flow; capacitance imaging sensor; capacitance sensors; capacitance tomography system; data acquisition; linear backprojection; oil-water-gas pipe flow; permittivity; reconstruction algorithm; three phase pipe flow imaging;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Advances in Sensors for Fluid Flow Measurement, IEE Colloquium on
Conference_Location :
London
Type :
conf
DOI :
10.1049/ic:19960579
Filename :
543312
Link To Document :
بازگشت