• DocumentCode
    187280
  • Title

    Representation of induced and transferred charge in the measurement signal from electrostatic sensors

  • Author

    Chao Wang ; Jingyu Zhang ; Yishun Zhang ; Yong Yan

  • Author_Institution
    Sch. of Electr. Eng. & Autom., Tianjin Univ., Tianjin, China
  • fYear
    2014
  • fDate
    12-15 May 2014
  • Firstpage
    1306
  • Lastpage
    1309
  • Abstract
    The electrostatic method with ring electrodes embedded in pipe walls is widely used for the measurement of dilute gas-solid two phase flow. The signal from electrostatic sensors contains not only the information about the induced charge when the charged particles move through the electrode, but also the information about transferred charge when the charged particles impact on the electrode wall. A current source equivalent model is built to study the sensing mechanism. The mean value of the signal is mainly generated by charged particles impacting on the electrode and charge transferring.
  • Keywords
    charge exchange; electrodes; electrostatic devices; flow measurement; flow sensors; pipe flow; two-phase flow; charged particles; current source equivalent model; dilute gas-solid two phase flow measurement; electrode wall; electrostatic method; electrostatic sensor; induced charge representation; measurement signal; pipe walls; ring electrodes; transferred charge representation; Atmospheric measurements; Current measurement; Electrodes; Electrostatic measurements; Electrostatics; Particle measurements; Sensors; charge transfer; dilute gas-solid two phase flow; electrostatic induction; electrostatic sensor; electrostatic signal;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement Technology Conference (I2MTC) Proceedings, 2014 IEEE International
  • Conference_Location
    Montevideo
  • Type

    conf

  • DOI
    10.1109/I2MTC.2014.6860956
  • Filename