DocumentCode :
1882633
Title :
Decreasing transient beam loading in RF cavities of U-70 accelerator
Author :
Lebedev, O.P.
Author_Institution :
IHEP, Protvino, Russia
Volume :
3
fYear :
1995
fDate :
1-5 May 1995
Firstpage :
1658
Abstract :
The U-70 RF system was worked out to operate with the injector-linac at 100 MeV energy. A wide RF range was (2.6-6.1) MHz. For the U-70 injector Booster the wide RF range decreased and now it is (5.5-6.1) MHz. This fact and simplest method of changing the parameters in RF ferrite dominated cavities allow one to increase of the equivalent value of the cavity capacitance for the main frequency by about a factor of 2.7 and increase of the value of the cavity gap capacitance by about a factor of 5. The experimental investigation of the U-70 RF cavities due to the injection of bunches from the Booster into the U-70 orbit, near transition and on main flat-top is presented
Keywords :
accelerator cavities; booster injectors; particle beam dynamics; proton accelerators; synchrotrons; 100 MeV; 5.1 to 6.1 MHz; RF cavities; RF ferrite dominated cavities; U-70 accelerator; cavity capacitance; cavity gap capacitance; injector-linac; transient beam loading; Acceleration; Capacitance; Equivalent circuits; Extraterrestrial measurements; Inductance; Life estimation; Particle beams; Radio frequency; Resonant frequency; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
Type :
conf
DOI :
10.1109/PAC.1995.505318
Filename :
505318
Link To Document :
بازگشت