DocumentCode :
1886285
Title :
Cable management arm airflow impedance study
Author :
Rubenstein, Brandon
Author_Institution :
Hewlett Packard Co., Fort Collins, CO
fYear :
2008
fDate :
28-31 May 2008
Firstpage :
577
Lastpage :
582
Abstract :
A heavily loaded cable management arm at the rear of a server system can have the visual appearance of presenting a significant obstruction to airflow. Tests were carried out to evaluate the level of airflow impedance presented by a fully cabled arm in a relatively low profile server system. This investigation reveals that airflow pressure drop due to the presence of the cable management arm is less than 2% of the overall system impedance at typical operating conditions. This level of impedance would cause a nearly imperceptible temperature rise within the system.
Keywords :
cables (electric); data communication equipment; electric impedance; network servers; cable management arm airflow impedance; heavily loaded cable management arm; low profile server system; Arm; Communication cables; Cooling; Energy management; Impedance; Performance evaluation; Power system management; Power system reliability; System testing; Temperature; CMA; arm; cable; flow; impedance; management; pressure;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Thermal and Thermomechanical Phenomena in Electronic Systems, 2008. ITHERM 2008. 11th Intersociety Conference on
Conference_Location :
Orlando, FL
ISSN :
1087-9870
Print_ISBN :
978-1-4244-1700-1
Electronic_ISBN :
1087-9870
Type :
conf
DOI :
10.1109/ITHERM.2008.4544320
Filename :
4544320
Link To Document :
بازگشت