Initial diagnostics commissioning results for the Advanced Photon Source (APS)
Author :
Lumpkin, A. ; Patterson, D. ; Wang, X. ; Kahana, E. ; Sellyey, W. ; Votaw, A. ; Yang, B. ; Fuja, R. ; Berg, W. ; Borland, M. ; Emery, L. ; Decker, G. ; Milton, S.
Author_Institution :
Argonne Nat. Lab., IL, USA
Volume :
4
fYear :
1995
fDate :
1-5 May 1995
Firstpage :
2473
Abstract :
Principal diagnostics systems have been installed and nearly all have been commissioned on the subsystems of the Advanced Photon Source (APS) facility. Data have been obtained on beam position, beam profile, current, beam loss rate, and synchrotron radiation monitors on both injector rings and most recently the main 7-GeV storage ring. Results for the 150- to 450-MeV electron beams in the accumulator ring, up to 7 GeV in the injector synchrotron, and 4.5 to 7 GeV in the SR will be presented
Keywords :
booster injectors; commissioning; electron accelerators; particle beam diagnostics; storage rings; synchrotrons; 150 to 450 MeV; 4.5 to 7 GeV; 7 GeV; APS; Advanced Photon Source; beam current monitor; beam loss rate monitor; beam position monitor; beam profile monitor; commissioning; diagnostics; electron beams; injector rings; synchrotron radiation monitor; Acceleration; Electron beams; Energy measurement; Laboratories; Linear particle accelerator; Positrons; Storage rings; Strontium; Synchrotrons; Undulators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1995., Proceedings of the 1995
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-2934-1
Type :
conf
DOI :
10.1109/PAC.1995.505588
Filename :
505588
Link To Document :
بازگشت