• DocumentCode
    1901014
  • Title

    Measurements of vacuum chamber impedance effects on the stored beam at CESR

  • Author

    Billing, M. ; Greenwald, Z. ; Hartung, W. ; Lou, W.R. ; Pisharody, M. ; Rogers, J. ; Sagan, D. ; Sikora, J.

  • Author_Institution
    Lab. of Nucl. Studies, Cornell Univ., Ithaca, NY, USA
  • Volume
    5
  • fYear
    1995
  • fDate
    1-5 May 1995
  • Firstpage
    3206
  • Abstract
    Within the last year CESR (Cornell Electron Storage Ring) has changed its mode of operation from 7 nearly equally spaced bunches in the two counter-rotating beams to 9 trains of 2 bunches in each of the beams as the next step in the upgrade of the facility toward higher beam currents and increased luminosity. The upgrade program has included work to understand and document the transverse stability of a single beam composed of trains of bunches. Initial results from this work will be reported here
  • Keywords
    beam handling techniques; electric impedance measurement; electron accelerators; particle beam diagnostics; particle beam stability; storage rings; vacuum apparatus; CESR; Cornell Electron Storage Ring; bunch trains; counterrotating beams; single beam; stored beam; transverse stability; upgrade program; vacuum chamber impedance effects measurements; Current measurement; Electron beams; Frequency; Impedance measurement; Laboratories; Niobium; Nuclear measurements; Particle beam measurements; Particle beams; Storage rings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1995., Proceedings of the 1995
  • Conference_Location
    Dallas, TX
  • Print_ISBN
    0-7803-2934-1
  • Type

    conf

  • DOI
    10.1109/PAC.1995.505830
  • Filename
    505830