The effect of coupling on luminosity [storage rings]
Author_Institution :
Lab. of Nucl. Studies, Cornell Univ., Ithaca, NY, USA
Abstract :
In a storage ring the existence of skew quadrupoles, solenoids, and other coupling elements breaks the independence of the horizontal and vertical motions. With the flat beams used in electron/positron colliding beam storage rings this coupling results in an increase in the vertical beam size with an attendant loss in luminosity. By defining a `badness´ parameter Bc the luminosity loss can be directly related to measurements of the coupling
Keywords :
colliding beam accelerators; electron accelerators; particle beam diagnostics; particle beam dynamics; storage rings; badness parameter; coupling; electron/positron storage rings; flat beams; luminosity; skew quadrupoles; solenoids; vertical beam size; Computer simulation; Degradation; Extraterrestrial measurements; Laboratories; Loss measurement; Optical coupling; Particle beams; Solenoids; Storage rings; Testing;