Title :
Corona discharge treatment
Abstract :
Various aspects of corona discharge treatment are reviewed. Particular attention is given to the Lissajous power measurement procedure; the significance of quartz, ceramic, or rubber as the dielectric in corona treaters; watt density considerations; and stabilizers and fatty acids
Keywords :
corona; discharges (electric); electrostatics; power measurement; Lissajous power measurement procedure; ceramic; corona discharge; dielectric; electrostatics; fatty acids; quartz; rubber; stabilizers; watt density; Breakdown voltage; Corona; Dielectric materials; Electric breakdown; Electrodes; Electrons; Frequency; Impedance matching; Ionization; Signal generators;
Conference_Titel :
Industry Applications Society Annual Meeting, 1993., Conference Record of the 1993 IEEE
Conference_Location :
Toronto, Ont.
Print_ISBN :
0-7803-1462-X
DOI :