Abstract :
This paper presents an OTA-based control system of active power filter for harmonic and reactive power compensation in power system. An SCR-full wave rectifier is used as an uncontrolled nonlinear load. A single phase control of shunt-VSI-APF is discussed for simplicity. This proposed OTA-based control circuit has the advantage of self-tuning, low cost, simple and small size circuitry compared to the use of high precision multiplier or digital processor. Theoretical analysis, design and simulation results of the OTA-circuit are provided. A prototype is being developed to demonstrate the performance of the control system.
Keywords :
active filters; compensation; control systems; operational amplifiers; power filters; power harmonic filters; reactive power control; rectifying circuits; thyristors; OTA; SCR; active power filter; control system; full wave rectifier; harmonic power compensation; nonlinear load; operational transconductance amplifier; reactive power compensation; silicon-controlled rectifier; single phase control; Active filters; Circuits; Control systems; Phase control; Power harmonic filters; Power system control; Power system harmonics; Power systems; Reactive power control; Rectifiers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Control Applications, 2003. CCA 2003. Proceedings of 2003 IEEE Conference on
Print_ISBN :
0-7803-7729-X
Type :
conf
DOI :
10.1109/CCA.2003.1223334
Filename :
1223334
Link To Document :
بازگشت