DocumentCode
1945397
Title
The Research on Detection Method of Battery Discharge
Author
Yue Liren ; Tang Yiquan ; Zhu Shuangdong
Author_Institution
Coll. of Inf. Sci. & Eng., Ningbo Univ., Ningbo, China
fYear
2011
fDate
5-7 Aug. 2011
Firstpage
1324
Lastpage
1327
Abstract
At present, there is low accuracy and single discharge mode existing in battery discharge systems. During detection procedure of battery discharge the parasitic resistance is the key factor that affects the measurement accuracy, thus one of the important measures to improve the detection accuracy of the battery discharge is to eliminate the influence of parasitic resistance. To solve the above problems, this paper introduces a battery discharge detection technique based on numerical control constant-current source and four terminal measurement. The research shows that the detection approach not only effectively eliminates the influence of parasitic resistance to measurement accuracy, but also achieves the unity of various discharge methods, which can better meet the dual requirements of manufacturers, including both the detection accuracy of battery discharge and multiple discharge methods.
Keywords
cells (electric); constant current sources; discharges (electric); numerical control; battery discharge system detection method; four terminal measurement; multiple discharge methods; numerical control constant-current source; parasitic resistance; single discharge mode; Batteries; Battery charge measurement; Current measurement; Discharges; Electrical resistance measurement; Resistance; Voltage measurement; battery discharge; discharge method; four-terminal measurement; numerical control constant-current source; parasitic resistance;
fLanguage
English
Publisher
ieee
Conference_Titel
Digital Manufacturing and Automation (ICDMA), 2011 Second International Conference on
Conference_Location
Zhangjiajie, Hunan
Print_ISBN
978-1-4577-0755-1
Electronic_ISBN
978-0-7695-4455-7
Type
conf
DOI
10.1109/ICDMA.2011.325
Filename
6052120
Link To Document