• DocumentCode
    1955372
  • Title

    Monitoring the DC third rail interface using an in-service train

  • Author

    Green, Scott R. ; Hickson, D. ; Ward, D. ; Roberts, Clive ; Weston, Paul ; Stewart, Edward

  • Author_Institution
    Selhurst Tramcare Depot, Southern Railway Ltd., London, UK
  • fYear
    2011
  • fDate
    29-30 Nov. 2011
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    This paper describes the background to, development and trials of a system fitted to in-service train which can measure the quality of the dynamic interface between shoegear and the third rail on the UK 750V DC network. The paper will demonstrate the early results showing the systems ability to pick out locations where the interface is performing abnormally and to detect the defects responsible for those deviations.
  • Keywords
    measurement systems; railway electrification; DC third rail interface monitoring system; UK DC network; dynamic interface quality; in-service train; shoegear; voltage 750 V; DC Third Rail Interface Monitoring;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Railway Condition Monitoring and Non-Destructive Testing (RCM 2011), 5th IET Conference on
  • Conference_Location
    Derby
  • Type

    conf

  • DOI
    10.1049/cp.2011.0588
  • Filename
    6191856