DocumentCode :
1956852
Title :
Estimation of reflected wave in carotid pulse wave for simple and noninvasive assessment of arterial stiffness
Author :
Saito, Masashi ; Yamamoto, Yuya ; Shibayama, Yuka ; Matsukawa, Mami ; Watanabe, Yoshiaki ; Furuya, Mio ; Asada, Takaaki
Author_Institution :
Lab. of Ultrasonic Electron., Doshisha Univ., Kyotanabe, Japan
fYear :
2010
fDate :
11-14 Oct. 2010
Firstpage :
1554
Lastpage :
1557
Abstract :
Evaluation of a pulse wave is effective for screening arteriosclerosis. The pulse wave is composed of two components, incident and reflected waves. Because attenuation of the reflected wave changes markedly due to the arterial stiffness, analyzing this wave is useful. In previous study, we proposed a separation technique of two components using observed pulse waves and blood flow velocity waveforms. We confirmed that maximum values of estimated reflected waves increased with age. However, the measurement of the blood flow still needs an ultrasonic diagnostic equipment, which results in a barrier for simple screening. In this study, empirical model functions of blood flow velocity are introduced for each age group. The functions were obtained by averaging the blood flow velocity waveforms after normalizing them by the time interval between maximum amplitude and incisura. We then investigated the applicability of these functions for the estimation of the reflected waves. In consequence, we found small differences between the amplitudes of reflected waves estimated by personal waveform and empirical model function. The idea of this empirical model function is reasonable and eliminates the use of ultrasonic diagnostic system.
Keywords :
biomedical ultrasonics; blood flow measurement; blood vessels; cardiovascular system; diseases; haemodynamics; physiological models; velocity measurement; arterial stiffness; blood flow measurement; blood flow velocity; carotid pulse wave; empirical model functions; reflected wave estimation; screening arteriosclerosis; ultrasonic diagnostic equipment; Acoustics; Blood flow; Fluid flow measurement; Hypertension; Pulse measurements; Sensors; Velocity measurement; Arterial stiffness; Blood flow velocity; Empirical model function; Pulse wave;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium (IUS), 2010 IEEE
Conference_Location :
San Diego, CA
ISSN :
1948-5719
Print_ISBN :
978-1-4577-0382-9
Type :
conf
DOI :
10.1109/ULTSYM.2010.5935690
Filename :
5935690
Link To Document :
بازگشت