DocumentCode
1968460
Title
Spectral quality of ALS U5.0 undulator and field error effects
Author
Wang, C. ; Marks, S. ; Kincaid, B.
Author_Institution
Lawrence Berkeley Lab., CA, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
1578
Abstract
The first insertion device of the Advanced Light Source (ALS), a U5.0 undulator, has been carefully adjusted and qualified with a specially designed magnetic measurement system. The magnetic field of the undulator has been fully mapped at a series of gaps with very high accuracy. Based upon these measured field data, we evaluate the radiation spectral quality of this device in terms of an ideal sinusoidal device and examine the field error effects. Moreover, the statistical correlation between the field errors and radiation degradation is examined by using the large quantity of magnetic field data sets accumulated in the process of adjusting and qualifying the U5.0 undulator
Keywords
beam handling equipment; electron accelerators; magnetic field measurement; storage rings; wigglers; ALS U5.0 undulator; Advanced Light Source; field error effects; first insertion device; magnetic field; magnetic measurement system; radiation spectral quality; spectral quality; Brightness; Computer errors; Degradation; Laboratories; Light sources; Magnetic analysis; Magnetic field measurement; Magnetic variables measurement; Storage rings; Undulators;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.309076
Filename
309076
Link To Document