A 30 MeV compact cyclotron devoted to medical radioactive isotope production is being built in CIAE. It was originally designed by IBA, Belgium. Some major modifications of the design have been taken. In order to improve the performance of the machine, magnet redesign and adjustment has to be undertaken. All equipment in the control room are already in position. RF systems, power supplies, vacuum and water cooling systems have been tested. The machine is in the final installation stage and ready for commissioning
Keywords
beam handling equipment; cyclotrons; physical instrumentation control; 30 MeV; CIAE; RF systems; control system; design; magnet; medical cyclotron; power supplies; radioisotope production; vacuum system; water cooling system; Acceleration; Cyclotrons; Ion beams; Ion sources; Isotopes; Magnetic separation; Particle beams; Radio frequency; Structural beams; System testing;