Abstract :
A novel integrated sensor system for indoor air quality (IAQ) measurement based on infrared absorption principle is developed; the system is designed to monitor and evaluate the indoor air quality according to Malaysian IAQ standard. It can measure the concentration of three gases; carbon dioxide (CO2), carbon monoxide (CO) and formaldehyde (CH2O) to the 1 part per million (ppm) level. The system consists of three elements; sensor for detection of the target gas, data acquisition via PIC microcontroller and the display of target gas concentrations. For a comprehensive integrated system, relative humidity and temperature measurements are incorporated.
Keywords :
air pollution measurement; carbon compounds; data acquisition; gas sensors; humidity measurement; infrared detectors; light absorption; optical sensors; organic compounds; temperature measurement; CO; CO2; Malaysian IAQ standard; PIC microcontroller; carbon dioxide; carbon monoxide; data acquisition; formaldehyde; indoor air quality measurement; infrared absorption principle; integrated sensor system; relative humidity; target gas detection; temperature measurement; Carbon dioxide; Chemical elements; Electromagnetic wave absorption; Gases; Infrared sensors; Infrared surveillance; Measurement standards; Monitoring; Sensor systems; Standards development;
Conference_Titel :
Signal Processing & Its Applications, 2009. CSPA 2009. 5th International Colloquium on
Conference_Location :
Kuala Lumpur
Print_ISBN :
978-1-4244-4151-8
Electronic_ISBN :
978-1-4244-4152-5
DOI :
10.1109/CSPA.2009.5069260