DocumentCode
1976192
Title
Magnetic measurement data of the injector synchrotron dipole magnets for the 7-GeV Advanced Photon Source
Author
Kim, K. ; Kim, S.H. ; Turner, L.R. ; Doose, C.L. ; Hogrefe, R. ; Merl, R.
Author_Institution
Argonne Nat. Lab., IL, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
2799
Abstract
The magnetic measurement data of the first 34 of the required 68 production magnets for the injector synchrotron are summarized. The magnetic measurement method of the field strength and field shape relative to a reference magnet is described. The standard deviation of the integrated field strength for the 34 magnets is 3.3×10-4 and the variation of the integrated field with transverse displacement of ±25 mm is less than 2.5×10-4
Keywords
beam handling equipment; magnetic field measurement; particle accelerator accessories; synchrotrons; 7-GeV Advanced Photon Source; field shape; field strength; injector synchrotron dipole magnets; integrated field strength; magnetic measurement data; Coils; Extraterrestrial measurements; Fitting; Lamination; Magnetic field measurement; Magnetic variables measurement; Magnets; Production; Shape measurement; Synchrotrons;