DocumentCode
1977810
Title
Design of a high brightness RF photoinjector for the SLAC Linac Coherent Light Source
Author
Rosenzweig, J. ; Serafini, L.
Author_Institution
Dept. of Phys., California Univ., Los Angeles, CA, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
3024
Abstract
The electron injector for the SLAC Linear Coherent Light Source (LCLS) must produce a low jitter, high brightness beam. This beam must be accelerated and longitudinally compressed to yield a sub-picosecond beam which radiates a burst of, self-amplified spontaneous emission X-rays upon passing through a long undulator. As the gain of this amplifier is very sensitive to the emittance, energy spread and peak current the electron source and subsequent transport, acceleration, and compression systems must reproducibly give a very high quality beam. The conceptual design of an RF photocathode gun which satisfies the requirements of the LCLS is presented here
Keywords
beam handling equipment; beam handling techniques; electron accelerators; electron guns; electron sources; linear accelerators; photocathodes; RF photocathode gun; SLAC Linear Coherent Light Source; conceptual design; electron injector; electron source; emittance; energy spread; high brightness RF photoinjector; high brightness beam; low jitter; peak current; self-amplified spontaneous emission X-rays; sub-picosecond beam; undulator; Acceleration; Brightness; Electron beams; Jitter; Light sources; Linear particle accelerator; Particle beams; Radio frequency; Spontaneous emission; X-rays;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.309538
Filename
309538
Link To Document