    Design of a high brightness RF photoinjector for the SLAC Linac Coherent Light Source

  • Author

    Rosenzweig, J. ; Serafini, L.

  • Author_Institution
    Dept. of Phys., California Univ., Los Angeles, CA, USA
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    3024
  • Abstract
    The electron injector for the SLAC Linear Coherent Light Source (LCLS) must produce a low jitter, high brightness beam. This beam must be accelerated and longitudinally compressed to yield a sub-picosecond beam which radiates a burst of, self-amplified spontaneous emission X-rays upon passing through a long undulator. As the gain of this amplifier is very sensitive to the emittance, energy spread and peak current the electron source and subsequent transport, acceleration, and compression systems must reproducibly give a very high quality beam. The conceptual design of an RF photocathode gun which satisfies the requirements of the LCLS is presented here
  • Keywords
    beam handling equipment; beam handling techniques; electron accelerators; electron guns; electron sources; linear accelerators; photocathodes; RF photocathode gun; SLAC Linear Coherent Light Source; conceptual design; electron injector; electron source; emittance; energy spread; high brightness RF photoinjector; high brightness beam; low jitter; peak current; self-amplified spontaneous emission X-rays; sub-picosecond beam; undulator; Acceleration; Brightness; Electron beams; Jitter; Light sources; Linear particle accelerator; Particle beams; Radio frequency; Spontaneous emission; X-rays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309538
  • Filename
    309538