DocumentCode
1979582
Title
Time comparison of atomic clocks using counter and GPS system
Author
Gamidov, R. ; Cetintas, Mustafa
Author_Institution
Tubitak, Gebze-Kocaeli, Turkey
Volume
1
fYear
1999
fDate
1999
Firstpage
268
Abstract
Two HP 5071A Cs atomic clocks were used as a reference to AOA GPS receivers TTRSA and TTR6 respectively. At the same time interval, these reference atomic clocks were compared using both GPS common view method (CVM) and time interval counter (TIG). The time differences between the atomic clocks were analyzed and compared in two types of measurement technique
Keywords
Global Positioning System; atomic clocks; calibration; measurement standards; radio receivers; AOA GPS receivers; Cs; GPS common view method; HP 5071A Cs atomic clocks; TTR6; TTRSA; counter; reference atomic clocks; time interval; time interval counter; Antenna measurements; Atomic clocks; Counting circuits; Erbium; Fluctuations; Global Positioning System; Receiving antennas; Satellites; Temperature sensors; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Frequency and Time Forum, 1999 and the IEEE International Frequency Control Symposium, 1999., Proceedings of the 1999 Joint Meeting of the European
Conference_Location
Besancon
ISSN
1075-6787
Print_ISBN
0-7803-5400-1
Type
conf
DOI
10.1109/FREQ.1999.840758
Filename
840758
Link To Document