• DocumentCode
    1979582
  • Title

    Time comparison of atomic clocks using counter and GPS system

  • Author

    Gamidov, R. ; Cetintas, Mustafa

  • Author_Institution
    Tubitak, Gebze-Kocaeli, Turkey
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    268
  • Abstract
    Two HP 5071A Cs atomic clocks were used as a reference to AOA GPS receivers TTRSA and TTR6 respectively. At the same time interval, these reference atomic clocks were compared using both GPS common view method (CVM) and time interval counter (TIG). The time differences between the atomic clocks were analyzed and compared in two types of measurement technique
  • Keywords
    Global Positioning System; atomic clocks; calibration; measurement standards; radio receivers; AOA GPS receivers; Cs; GPS common view method; HP 5071A Cs atomic clocks; TTR6; TTRSA; counter; reference atomic clocks; time interval; time interval counter; Antenna measurements; Atomic clocks; Counting circuits; Erbium; Fluctuations; Global Positioning System; Receiving antennas; Satellites; Temperature sensors; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency and Time Forum, 1999 and the IEEE International Frequency Control Symposium, 1999., Proceedings of the 1999 Joint Meeting of the European
  • Conference_Location
    Besancon
  • ISSN
    1075-6787
  • Print_ISBN
    0-7803-5400-1
  • Type

    conf

  • DOI
    10.1109/FREQ.1999.840758
  • Filename
    840758