• DocumentCode
    1994182
  • Title

    High-resolution, high-contrast ultrasound imaging using a prototype dual-frequency transducer in-vitro and in-vivo studies

  • Author

    Gessner, Ryan ; Lukacs, Marc ; Lee, Mike ; Foster, F. Stuart ; Dayton, Paul A.

  • Author_Institution
    Joint Dept. of Biomed. Eng., Univ. of North Carolina & North Carolina State Univ., Chapel Hill, NC, USA
  • fYear
    2009
  • fDate
    20-23 Sept. 2009
  • Firstpage
    275
  • Lastpage
    278
  • Abstract
    Recently, there has been a great interest in the capabilities of high-resolution ultrasound imaging. One of the applications is imaging blood vessels to assess tumor growth and response to therapy. Due to their nonlinear response, microbubble contrast agents scatter ultrasound energy at frequencies higher and lower than the imaging frequency. To maximize ultrasound scatter, the imaging frequency should be near the microbubble resonant frequency. Previously, this was not possible with high-frequency imaging systems because most contrast agents resonate at 1-10 MHz and the systems pulse at higher frequencies. We have developed a unique dual-frequency confocal transducer which excites microbubbles at low frequencies, near their resonance, and detects their emitted high-frequency energy at greater than 15 MHz. With this imaging approach, we have attained an average improvement in contrast-to-tissue ratio of 12.3 dB over standard b-mode imaging for MI between 0.5 and 0.65 with spatial resolution near that of the high-frequency element (30 MHz). This method is less susceptible to tissue motion corruption than power-Doppler because it does not rely on signal-decorrelation. Because of this, dual-frequency imaging can be used for flow imaging without respiratory gating.
  • Keywords
    biomedical ultrasonics; blood vessels; bubbles; haemodynamics; tumours; ultrasonic imaging; ultrasonic transducers; blood vessels; contrast-to-tissue ratio; dual-frequency confocal transducer; dual-frequency imaging; dual-frequency transducer; flow imaging; frequency 1 MHz to 10 MHz; high-resolution high-contrast ultrasound imaging; microbubble contrast agents; microbubble resonant frequency; respiratory gating; therapy response; tissue motion corruption; tumor growth; ultrasonic scattering; Biomedical imaging; Blood vessels; High-resolution imaging; In vitro; Neoplasms; Prototypes; Resonant frequency; Scattering; Ultrasonic imaging; Ultrasonic transducers; Contrast agents; harmonic imaging; ultrasound;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2009 IEEE International
  • Conference_Location
    Rome
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4244-4389-5
  • Electronic_ISBN
    1948-5719
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2009.5441548
  • Filename
    5441548