DocumentCode
2017217
Title
A temperature-controlled system for loss measurement of transformer used in switched-mode power supply
Author
Sun, Di ; Fang, Wenxiao ; Lu, Jiale ; He, Xiaoqi ; Zhang, Xiaowen
Author_Institution
School of Material and Energy Resources, Guangdong University of Technology, Guangzhou, China
fYear
2015
fDate
11-14 Aug. 2015
Firstpage
118
Lastpage
121
Abstract
The switch-mode power supply (SMPS) is being widely used in various fields. The reliability of SMPS is directly affected by the degradation and failure of magnetic component of transformer. It is well known that the loss of the magnetic component of transformer consist of iron loss and copper loss. In this paper, The pros and cons of several common loss measurement methods are discussed and a brief overview of temperature-controlled system for loss measurement of transformer in SMPS is proposed. The system can achieve these goals, within specified flux density and high frequency ranges, and at different temperatures, with high speed and accuracy, then MATLAB programming for data analysis and loss calculation. By doing this, The system can rapidly judge whether the damage of SMPS is caused by the loss of magnetic component.
Keywords
Core loss; Current measurement; Loss measurement; Magnetic cores; Switched-mode power supply; Temperature measurement; Voltage measurement; Core loss measurement; Reliability; Switch-mode power supply (SMPS); Temperature; Transformer;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Packaging Technology (ICEPT), 2015 16th International Conference on
Conference_Location
Changsha, China
Type
conf
DOI
10.1109/ICEPT.2015.7236556
Filename
7236556