DocumentCode
2034151
Title
X-rays from laboratory sparks in air: The relationship between runaway electrons and the electric field
Author
March, Victor ; Montanyà, Joan ; Romero, David ; Solà, Glòria ; Van der Welde, Oscar
Author_Institution
Dept. of Electr. Eng., Technol. Univ. of Catalonia, Terrassa, Spain
fYear
2012
fDate
2-7 Sept. 2012
Firstpage
1
Lastpage
7
Abstract
This article presents an experiment in which the gap distance was varied between 46 and 84 cm. Series of 15 voltage impulses were applied for each distance and different peak voltages with a rise time of 600 ns. The results of a total of 20 series of impulse voltages show that emissions depend on the electric field derivative within the gap.
Keywords
X-rays; electric fields; electrons; lightning protection; sparks; X-rays; electric field; laboratory sparks; natural lightning; runaway electrons; time 600 ns; voltage impulses; Correlation; Electrodes; Runaway electrons; TGF; X-rays;
fLanguage
English
Publisher
ieee
Conference_Titel
Lightning Protection (ICLP), 2012 International Conference on
Conference_Location
Vienna
Print_ISBN
978-1-4673-1898-3
Electronic_ISBN
978-1-4673-1896-9
Type
conf
DOI
10.1109/ICLP.2012.6344375