  • Abstract
    The current real-time PCR (polymerase chain reaction) platforms, which can detect and quantify several target DNA simultaneously, are equipped with discrete optics and detectors for different fluorescence wavelengths. However, the optical loss, due to the different lengths of the channels for several dyes, lowers the performance of fluorescence detection. Especially on the PCR platforms of lab-on-a-chip system, for the dispersion of the fluorescence in the micro fluidic channels, the received fluorescence is much lower than the emitted. To enhance the received intensity on the detection system is therefore a critical issue. The proposed fluorescence detection system, composing of an ultra-sensitive spectrometer, can provide continuous wavelength detection and can be employed for multiple DNA quantification and genotyping in a single reaction. For the tests to the genotyping ability, the melting temperatures of B type HBV and C type HBV can be distinguished by the difference of 1.1degC.The test results in this research show the same degree of sensitivity for DNA quantification and reproducibility within five intra assay samples as compared with a commercial one
  • Keywords
    DNA; fluorescence; lab-on-a-chip; microfluidics; microorganisms; B type HBV melting temperature; C type HBV melting temperature; Hepatitis B virus; Hepatitis C virus; continuous wavelength detection; fluorescence detection system; fluorescence dispersion; genotyping ability; microfluidic channels; multiple DNA genotyping; multiple DNA quantification; optical loss; polymerase chain reaction; real time PCR lab-on-a-chip; received intensity; simultaneous quantification; target DNA detection; target DNA quantification; ultrasensitive spectrometer; DNA; Fluorescence; Lab-on-a-chip; Liver diseases; Optical detectors; Optical losses; Optical polymers; Optical sensors; Stimulated emission; Testing; HBV; HCV; Real-time PCR;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nano/Micro Engineered and Molecular Systems, 2006. NEMS '06. 1st IEEE International Conference on
  • Conference_Location
    Zhuhai
  • Print_ISBN
    1-4244-0139-9
  • Electronic_ISBN
    1-4244-0140-2
  • Type

    conf

  • DOI
    10.1109/NEMS.2006.334721
  • Filename
    4134951