    Epoxy/mica insulation condition assessment using AC current method

  • Author

    Hao, Yanpeng ; Wang, Guoli ; Xie, Hengkun

  • Author_Institution
    State Key Lab. of Electr. Insulation for Power Equip., Xi´´an Jiaotong Univ., China
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    705
  • Lastpage
    708
  • Abstract
    In this paper, accelerated multistresses aging tests in the laboratory have been conducted on electric machine stator epoxy/mica insulation. In different aging stages, AC current tests and breakdown tests were performed. The characteristics of AC current of stator insulation were analyzed and the voltage Upi2, at which the second point of current rapid increase appears, was investigated. The correlation between the voltage Upi2 and the residual breakdown voltage was also analyzed
  • Keywords
    ageing; electric machines; epoxy insulation; insulation testing; life testing; machine insulation; machine testing; mica; stators; AC current tests; Upi2 voltage; accelerated multistresses aging tests; aging stages; breakdown tests; electric machine stator epoxy/mica insulation; residual breakdown voltage; Accelerated aging; Dielectrics and electrical insulation; Electric breakdown; Electric machines; Insulation testing; Laboratories; Life estimation; Performance evaluation; Stators; Voltage;