• DocumentCode
    2069409
  • Title

    Case study of product defects found by air discharge mode ESD but missed by contact ESD

  • Author

    Soohoo, Kwok ; Wielgos, Michael

  • Author_Institution
    IBM Corp., Poughkeepsie, NY
  • fYear
    2008
  • fDate
    19-23 May 2008
  • Firstpage
    136
  • Lastpage
    139
  • Abstract
    Product ESD immunity testing to meet European EMC Directive called for air discharge and contact mode ESD tests; however when testing product with exposed metal areas then contact mode is the specified method. In this paper 2 cases are documented to demonstrate that air discharge mode used exclusively on product with plastic or insulated covers/chassis should not be taken a backseat to contact ESD for exposed metal areas. In fact both methods should be used to complement each other when testing products.
  • Keywords
    electromagnetic interference; electrostatic discharge; failure analysis; immunity testing; ESD immunity testing; air discharge mode ESD; contact ESD; Connectors; Electromagnetic compatibility; Electrostatic discharge; Gaskets; IEC standards; Immunity testing; Impedance; Logic; Surface discharges; System testing;