• DocumentCode
    2092003
  • Title

    Atomic hydrogen maser group for Chinese positioning system

  • Author

    Wei-Qun Zhang ; Guan-Zhong Wang ; Chuan-Fu Lin ; Yi-Ping Zhang ; Zao-Cheng Zhai

  • Author_Institution
    Shanghai Obs., Chinese Acad. of Sci., Shanghai
  • fYear
    2004
  • fDate
    5-7 April 2004
  • Firstpage
    420
  • Lastpage
    420
  • Abstract
    Three hydrogen masers were put into operation at the earth station of Chinese positioning system four years ago. We have made many physical and electronics improvement on these hydrogen masers for improving the long-term performance. The hydrogen maser´s size is 110 cm(high)*54 cm(width)*73 cm(depth). It weighs 250 kg. By performance comparing with each other, we may choose the best one as a frequency reference for this system. A kind of cavity auto-tuning system was applied for improving of the long-term performance. Performance evaluation showed the frequency stability is in the order of E-15 for time interval from 80s to 1 day and the phase noise (SSB) is -150 dBc/100 Hz. The environmental sensitivities are also given in this paper.
  • Keywords
    gas lasers; laser tuning; masers; Chinese positioning system; atomic hydrogen maser; cavity autotuning system; earth station; environmental sensitivities; frequency 100 Hz; performance evaluation; phase noise; Atomic hydrogen maser; Cavity auto-tuning; Frequency accuracy; Frequency stability;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    Frequency and Time Forum, 2004. EFTF 2004. 18th European
  • Conference_Location
    Guildford
  • ISSN
    0537-9989
  • Print_ISBN
    0-86341-384-6
  • Type

    conf

  • Filename
    5074987