DocumentCode :
2093922
Title :
Problems caused by insufficient electrical isolation in RF-measurement setups
Author :
Haake, Kai ; Haseborg, Jan-Luiken Ter
Author_Institution :
Dept. of Meas. Eng., Hamburg Univ. of Technol., Germany
Volume :
1
fYear :
2005
fDate :
8-12 Aug. 2005
Firstpage :
256
Abstract :
This paper analyzes a disturbance effect that occurs at measurement setups with looped ground connections. It is shown how this effect arises by measuring it with a special setup. Further the effect is deconstructed in detail using a simplified model. Hence steps to be taken are shown in order to suppress this disturbance effect.
Keywords :
earthing; interference suppression; transformers; RF-measurement setups; disturbance effect suppression; electrical isolation; looped ground connections; Cable shielding; Coaxial cables; Conductors; Current measurement; Electric variables measurement; Electromagnetic compatibility; Electromagnetic measurements; Impedance; TEM cells; Voltage;