• DocumentCode
    2098167
  • Title

    Influence of ground plane to distance dependence leaked electric field from power line

  • Author

    Watanabe, Yousuke ; Tokuda, Masamitsu

  • Author_Institution
    Res. Div. in Eng., Musashi Inst. of Technol., Tokyo, Japan
  • Volume
    3
  • fYear
    2005
  • fDate
    8-12 Aug. 2005
  • Firstpage
    1008
  • Abstract
    In this paper, we focused attention on the system that used the MHz band in a power line communication, and calculated the influence of electric condition of ground plane to distance dependence and electric field distribution of leaked electric field by method of moments. As a result, we understood the standard ground attenuated leaked electric field to distance as not 20 dB/dec but 40 dB/dec. And we understood the almost uniform attenuation in the standard ground independency of direction from the electric field distribution.
  • Keywords
    carrier transmission on power lines; electric field effects; electromagnetic interference; method of moments; distance dependence; electric condition; electric field distribution; ground plane; leaked electric field; method of moments; power line; power line communication; uniform attenuation; Attenuation; Data communication; Electromagnetic fields; Frequency; Moment methods; Power engineering and energy; Power line communications; Power supplies; Power system modeling; Programmable control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2005. EMC 2005. 2005 International Symposium on
  • Print_ISBN
    0-7803-9380-5
  • Type

    conf

  • DOI
    10.1109/ISEMC.2005.1513673
  • Filename
    1513673