    False operation of protective relays in Oman Electricity Power System & its remedies

  • Author

    Sharkh, M.F.A. ; Sharkh, Osama Abu ; Alkhusaibi, Thani M. ; Alhadi, Hilal S.

  • Author_Institution
    Abu-Sharkh Tech. Consulting Office, Muscat
  • fYear
    2008
  • fDate
    12-15 March 2008
  • Firstpage
    255
  • Lastpage
    259
  • Abstract
    In this paper, we conduct a study to clarify the difficulties which affected the operations of the protective relays in the Oman Electricity Power System and the steps which were taken to overcome these difficulties. A single line to ground fault on the network may cause the tripping of phase loads and reduce the speed of three phase inductive loads. This in turn causes an over current trip on the 11 and 33 kV feeders after the fault is cleared. The bank capacitors, used in the system, should not trip during the dip of voltage to avoid any further increase. The settings of the earth fault relays should be adjusted taking into consideration the ground resistance and the length of the distribution lines. A load shedding arrangement for 33 kV feeders should be used to avoid the tripping of a second transformer in the feeder transformer arrangement set. Distribution feeders should not be connected with the bus bars of the power stations. Under speed protective devices should not operate on frequencies more than 47.5 Hz. New types of relays should be used after testing it on the existing operating system.
  • Keywords
    power system faults; power system protection; power system relaying; power transformers; relay protection; Oman electricity power system; bank capacitors; distribution feeders; distribution lines; earth fault relays; false operation; feeder transformer arrangement set; ground resistance; load shedding; protective relays; single line to ground fault; three phase inductive loads; Bars; Capacitors; Frequency; Power generation; Power system faults; Power system protection; Power system relaying; Protective relaying; Relays; Voltage fluctuations; Feeder Transformer; Footing Resistance; Lightning Arrestors; Protictive Relays; Under frequancy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power System Conference, 2008. MEPCON 2008. 12th International Middle-East
  • Conference_Location
    Aswan
  • Print_ISBN
    978-1-4244-1933-3
  • Electronic_ISBN
    978-1-4244-1934-0
  • Type

    conf

  • DOI
    10.1109/MEPCON.2008.4562357
  • Filename
    4562357