Title :
High Rate Photon Counting CT Using Parallel Digital PET Electronics
Author :
Riendeau, Joel ; Bérard, Philippe ; Viscogliosi, Nicolas ; Tétrault, Marc-André ; Lemieux, François ; Lecomte, Roger ; Fontaine, Réjean
fYear :
2007
fDate :
April 29 2007-May 4 2007
Firstpage :
1
Lastpage :
8
Abstract :
Recent developments in detectors and electronics enable both positron emission tomography (PET) and X-ray computed tomography (CT) data to be acquired concurrently using the same detection front-end for dual-modality PET/CT imaging. Moreover, it would potentially allow substantial reduction of cost and housing size, in addition to facilitating image fusion. However, the lower energy signals (~60 keV vs. 511 keV) and higher photon flux per pixel (>1 Mcps vs. 10 kcps) in CT relative to PET cause significant pile-up and deadtime in CT data acquired in photon counting mode. A digital signal processing method was developed and implemented to improve processing of detector signals sampled at low frequency (~45 MHz) in presence of pile-up. The method consists in digitally subtracting the detector impulse response at the output of the preamplifier to restore the signal baseline for more accurate energy estimation. When compared to a fixed threshold counting technique, the proposed method features better noise immunity, higher energy resolution and 50% higher rates measured at an estimated true rate of 2.75 Mcps, making CT integration within modern digital PET hardware feasible.
Keywords :
computerised tomography; noise; positron emission tomography; scintillation counters; transient response; X-ray computed tomography; deadtime; detector impulse response; digital signal processing; dual-modality PET-CT imaging; front-end detection; high rate photon counting; higher energy resolution; image fusion facility; noise immunity; parallel digital PET electronics; photon flux; positron emission tomography scintillator; preamplifier output; signal baseline; Computed tomography; Costs; Digital signal processing; Image fusion; Optical imaging; Positron emission tomography; Signal processing; X-ray detection; X-ray detectors; X-ray imaging; Computed tomography; PET/CT; photon-counting;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Real-Time Conference, 2007 15th IEEE-NPSS
Conference_Location :
Batavia, IL
Print_ISBN :
978-1-4244-0866-5
Electronic_ISBN :
978-1-4244-0867-2
Type :
conf
DOI :
10.1109/RTC.2007.4382766
Filename :
4382766
Link To Document :
بازگشت