• DocumentCode
    2117208
  • Title

    The Multipoint Detection of Pulse Signal and Information Fusion Based on ARM

  • Author

    Junhong, Wang ; Yunbo, Guo ; Dawei, Wang ; Zongrui, Li

  • Author_Institution
    Electron. Eng. Dept., North China Inst. of Astronaut. Eng., Langfang
  • Volume
    2
  • fYear
    2008
  • fDate
    20-22 Dec. 2008
  • Firstpage
    612
  • Lastpage
    615
  • Abstract
    A detection method of multipoint pulse signal based on ARM9 is presented in this paper. Pulse signals are detected which are on the three parts of wrist, "Cun" "Guan" "Chi", neck artery, and the fingertip. After isolated, amplified, and digitized, Pulse signal enters a DSP anti-interference filter, in which EMG and power frequency signal must be filtered out especially. By using information fusion technology and through GPRS, compared with expert system of the medical service centre, the system can analysis the userpsilas health status. At last cardiovascular-related parameters are displayed on LCD.
  • Keywords
    electromyography; expert systems; medical signal detection; packet radio networks; sensor fusion; ARM9; DSP anti-interference filter; EMG; GPRS; cardiovascular-related parameters; expert system; information fusion; medical service centre; multipoint pulse signal detection; power frequency signal; ARM9; GPRS; Information Fusion; PulseSignal;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Information Science and Engineering, 2008. ISISE '08. International Symposium on
  • Conference_Location
    Shanghai
  • Print_ISBN
    978-1-4244-2727-4
  • Type

    conf

  • DOI
    10.1109/ISISE.2008.112
  • Filename
    4732468