• DocumentCode
    2132579
  • Title

    Quick comparison of QHR systems using a 100 ohm transfer resistor

  • Author

    Satrapinski, A. ; Seppa, H. ; Schumacher, B. ; Warnecke, P. ; Delahaye, F. ; Poirier, W. ; Piquemal, F.

  • Author_Institution
    VTT Autom., Espoo, Finland
  • fYear
    2000
  • fDate
    14-19 May 2000
  • Firstpage
    560
  • Lastpage
    561
  • Abstract
    A resistance comparison carried out with a temperature and pressure stabilized 100 /spl Omega/ standard resistor was performed in November and December 1998. The participants were BIPM, BNM-LCIE (France), PTB (Germany) and VTT (Finland)-pilot. The comparison results agree within 4/spl middot/10/sup -9/ with a combined standard uncertainty of 11/spl middot/10/sup -9/.
  • Keywords
    electric resistance measurement; measurement standards; measurement uncertainty; quantum Hall effect; resistors; transfer standards; 100 ohm; AC-DC resistance standard; combined standard uncertainty; pressure stabilized; quantum Hall resistance standards; resistance bridge; resistance comparison; standard resistor; temperature stabilized; transfer resistor; Bridges; Control systems; Electrical resistance measurement; Laboratories; Q measurement; Resistors; Temperature control; Temperature sensors; Thermistors; Transportation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2000 Conference on
  • Conference_Location
    Sydney, NSW, Australia
  • Print_ISBN
    0-7803-5744-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2000.851131
  • Filename
    851131