• DocumentCode
    2134651
  • Title

    High efficiency SVM technique for VSI

  • Author

    Attaianese, C. ; Capraro, D. ; Tomasso, G.

  • Author_Institution
    Dept. of Autom., Electromagnetism, Inf. Sci. & Ind. Math., Univ. of Cassino, Italy
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    269
  • Lastpage
    274
  • Abstract
    A space vector modulation technique for voltage source inverter which takes into account the power modules switching losses is presented in the paper. It is based on three digital separate circuits, which generate the modulation switching pattern by using a clock unit with three separate programmable frequency divisors. In particular, for each leg of the inverter, the switching frequency can be selected on the base of the instantaneous value of the corresponding phase current. In this way, a modulation technique can be carried out in such a way as to keep the power modules losses lower than a maximum value and to reduce the current harmonic content.
  • Keywords
    harmonics suppression; invertors; losses; modulation; power conversion harmonics; switching circuits; VSI; clock unit; current harmonic content reduction; digital separate circuits; instantaneous value; modulation switching pattern; modulation technique; power modules losses; power modules switching losses; programmable frequency divisors; space vector modulation; voltage source inverter; Clocks; Digital modulation; Frequency conversion; Inverters; Modulation coding; Multichip modules; Support vector machines; Switching circuits; Switching loss; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advanced Motion Control, 2002. 7th International Workshop on
  • Print_ISBN
    0-7803-7479-7
  • Type

    conf

  • DOI
    10.1109/AMC.2002.1026929
  • Filename
    1026929