DocumentCode
2134651
Title
High efficiency SVM technique for VSI
Author
Attaianese, C. ; Capraro, D. ; Tomasso, G.
Author_Institution
Dept. of Autom., Electromagnetism, Inf. Sci. & Ind. Math., Univ. of Cassino, Italy
fYear
2002
fDate
2002
Firstpage
269
Lastpage
274
Abstract
A space vector modulation technique for voltage source inverter which takes into account the power modules switching losses is presented in the paper. It is based on three digital separate circuits, which generate the modulation switching pattern by using a clock unit with three separate programmable frequency divisors. In particular, for each leg of the inverter, the switching frequency can be selected on the base of the instantaneous value of the corresponding phase current. In this way, a modulation technique can be carried out in such a way as to keep the power modules losses lower than a maximum value and to reduce the current harmonic content.
Keywords
harmonics suppression; invertors; losses; modulation; power conversion harmonics; switching circuits; VSI; clock unit; current harmonic content reduction; digital separate circuits; instantaneous value; modulation switching pattern; modulation technique; power modules losses; power modules switching losses; programmable frequency divisors; space vector modulation; voltage source inverter; Clocks; Digital modulation; Frequency conversion; Inverters; Modulation coding; Multichip modules; Support vector machines; Switching circuits; Switching loss; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Advanced Motion Control, 2002. 7th International Workshop on
Print_ISBN
0-7803-7479-7
Type
conf
DOI
10.1109/AMC.2002.1026929
Filename
1026929
Link To Document