• DocumentCode
    2164285
  • Title

    Energy Measurement Audit and Its Implementation in Coal-Fired Power Plant

  • Author

    Li, Yong ; Jiang, Tie-Liu ; Wang, Jian-Jun ; Lu, Li-kun ; Sun, Hao-Ran

  • Author_Institution
    Sch. of Energy & Mech. Eng., Northeast Dianli Univ., Jilin, China
  • fYear
    2009
  • fDate
    20-22 Sept. 2009
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper addresses energy measurement audit in coal-fired power plant. Energy audit, as an effective energy-saving and emission-reducing measure, was launched in thousands of high energy-consuming enterprises in China in 2006. The big part of energy audit is energy measurement audit. In this paper, the work center of energy measurement is obtained by analyzing the contents and characteristics of energy measurement works. According to Chinese standard, the basic requirement for equipping rate of the measuring instruments of energy in each class of organization and major energy-consuming equipment is introduced. A case of energy measurement audit in a coal-fired power plant is given. Auditing results show the equipping rate of the measuring instruments of most kinds of energy is unqualified.
  • Keywords
    auditing; energy consumption; energy measurement; steam power stations; China; coal-fired power plant; emission reducing measure; energy measurement audit; energy saving; energy-consuming equipment; high energy-consuming enterprises; Energy management; Energy measurement; Energy resources; Humans; Instruments; Measurement standards; Power generation; Power generation economics; Power measurement; Sun;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Management and Service Science, 2009. MASS '09. International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-4638-4
  • Electronic_ISBN
    978-1-4244-4639-1
  • Type

    conf

  • DOI
    10.1109/ICMSS.2009.5304422
  • Filename
    5304422