• DocumentCode
    2175270
  • Title

    Determination of equivalent circuit parameters of a direct drive wind power generator

  • Author

    Brasas, Frank ; Germishuizen, Johannes

  • Author_Institution
    Dept. of Sustainable Power Conversion (SPW), Siemens AG Ruhstorf, Ruhstorf an der Rott, Germany
  • fYear
    2012
  • fDate
    2-5 Sept. 2012
  • Firstpage
    201
  • Lastpage
    206
  • Abstract
    The equivalent circuit inductances of a direct drive wind power generator are important for the inverter control parameters. Inverter manufactures insist on knowing the exact values. There are several difficulties to overcome when calculating the synchronous inductances. A challenge in the inductance calculation is the separation of the flux linkage component due to the permanent magnets. This paper presents a unique method to accurately calculate the inductances from the machine characteristics.
  • Keywords
    electric generators; equivalent circuits; inductance; invertors; machine theory; wind power plants; direct drive wind power generator; equivalent circuit inductance; equivalent circuit parameter; flux linkage; inverter control parameter; permanent magnet; synchronous inductance; Couplings; Equivalent circuits; Finite element methods; Generators; Inductance; Mathematical model; Permanent magnets; 2D Functions; cross-coupling effect; direct drive; flux linkage; inductance calculation; performance calculation; permanent magnet machines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines (ICEM), 2012 XXth International Conference on
  • Conference_Location
    Marseille
  • Print_ISBN
    978-1-4673-0143-5
  • Electronic_ISBN
    978-1-4673-0141-1
  • Type

    conf

  • DOI
    10.1109/ICElMach.2012.6349864
  • Filename