DocumentCode
2175270
Title
Determination of equivalent circuit parameters of a direct drive wind power generator
Author
Brasas, Frank ; Germishuizen, Johannes
Author_Institution
Dept. of Sustainable Power Conversion (SPW), Siemens AG Ruhstorf, Ruhstorf an der Rott, Germany
fYear
2012
fDate
2-5 Sept. 2012
Firstpage
201
Lastpage
206
Abstract
The equivalent circuit inductances of a direct drive wind power generator are important for the inverter control parameters. Inverter manufactures insist on knowing the exact values. There are several difficulties to overcome when calculating the synchronous inductances. A challenge in the inductance calculation is the separation of the flux linkage component due to the permanent magnets. This paper presents a unique method to accurately calculate the inductances from the machine characteristics.
Keywords
electric generators; equivalent circuits; inductance; invertors; machine theory; wind power plants; direct drive wind power generator; equivalent circuit inductance; equivalent circuit parameter; flux linkage; inverter control parameter; permanent magnet; synchronous inductance; Couplings; Equivalent circuits; Finite element methods; Generators; Inductance; Mathematical model; Permanent magnets; 2D Functions; cross-coupling effect; direct drive; flux linkage; inductance calculation; performance calculation; permanent magnet machines;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines (ICEM), 2012 XXth International Conference on
Conference_Location
Marseille
Print_ISBN
978-1-4673-0143-5
Electronic_ISBN
978-1-4673-0141-1
Type
conf
DOI
10.1109/ICElMach.2012.6349864
Filename
6349864