• DocumentCode
    2178262
  • Title

    Enhanced Coagulation/Electro-Flotation Process for Algae Removal

  • Author

    Shi, Jun ; Xu, Li-Ke ; Deng, Hui-Ping

  • Author_Institution
    State Key Lab. of Pollution Control & Resources Reuse, Tongji Univ., Shanghai, China
  • fYear
    2010
  • fDate
    24-26 Aug. 2010
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper described the reductions of Microcystis aeruginosa and Anabaena flos-aquae using enhanced coagulation/electro- flotation process. A L9(34) orthogonal test including pH value, PAC doses, electric current and coagulation time is designed to remove algae in paper. Analysis of the removal of two major water-bloom algaes, viz Microcystis aeruginosa and Anabaena flos-aquae is addressed in paper by enhanced coagulation/electro-flotation process. The best removal of Microcystis aeruginosa and Anabaena flos-aquae achieved 93.33% and 96.47% respectively. The analysis of variance and range to the result of experiment indicates that coagulation process plays major role and pH value has the most remarkable influence.
  • Keywords
    coagulation; microorganisms; pH; water pollution; Anabaena flos-aquae; Microcystis aeruginosa; PAC doses; algae removal; coagulation; electric current; electro-flotation process; orthogonal test; pH value; water-bloom algae; Acoustics; Algae; Coagulation; Filtration; Lakes; Surface treatment; Water resources;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Management and Service Science (MASS), 2010 International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-5325-2
  • Electronic_ISBN
    978-1-4244-5326-9
  • Type

    conf

  • DOI
    10.1109/ICMSS.2010.5577370
  • Filename
    5577370