DocumentCode :
2182344
Title :
The influence of the broken bar fault on the magnetic field and electromagnetic torque in 3-phase induction motors
Author :
Spyropoulos, Dionysios V. ; Gyftakis, Konstantinos N. ; Kappatou, Joya ; Mitronikas, Epaminondas D.
fYear :
2012
fDate :
2-5 Sept. 2012
Firstpage :
1868
Lastpage :
1874
Abstract :
Broken bar faults are common in induction cage motors and can cause a variety of problems. This is the reason why there is continuous research on techniques for prompt detection. In this work a study of the influences of the broken bar fault to the electromagnetic characteristics of the induction motor is presented, using an asynchronous cage motor and FEM analysis. To this direction two models have been created and studied: a healthy one and a model with a broken bar fault. Additionally, a new approach on the detection of the broken rotor bar fault through the electromagnetic torque monitoring is suggested.
Keywords :
finite element analysis; induction motors; torque; 3-phase induction motors; FEM analysis; broken bar fault; electromagnetic torque; induction cage motors; magnetic field; prompt detection; Air gaps; Harmonic analysis; Induction motors; Rotors; Stators; Torque; Broken Rotor Bar; Fault detection; Fault diagnosis; Finite Element Methods; Induction Motors; Torque Measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines (ICEM), 2012 XXth International Conference on
Conference_Location :
Marseille
Print_ISBN :
978-1-4673-0143-5
Electronic_ISBN :
978-1-4673-0141-1
Type :
conf
DOI :
10.1109/ICElMach.2012.6350136
Filename :
6350136