The main gap discharge types and mechanism of a triggered vacuum gaps
Author
Shang, W. ; Damstra, G.C.
Volume
1
fYear
1996
fDate
21-26 Jul 1996
Firstpage
51
Abstract
In the positive mode of triggered vacuum gaps, the discharge has three different types: sustained breakdown without chopping (SB); sustained breakdown with chopping (SBC); and nonsustained breakdown with chopping (NSBC). In the negative mode, only sustained breakdown occurs. The influence of main gap voltage, residual gas pressure and the trigger type have been investigated based on the type of main gap discharge. It is shown that the type of main gap discharge has a statistical property. Finally, the discharge mechanism is discussed based on the trigger plasma property
Keywords
discharges (electric); electric breakdown; insulation testing; vacuum breakdown; vacuum insulation; chopping; discharge mechanism; insulation breakdown testing; main gap voltage; negative main gap discharge; nonsustained breakdown; positive main gap discharge; residual gas pressure; statistical property; sustained breakdown; trigger type; triggered vacuum gaps; Cathodes; Circuit testing; Dielectrics and electrical insulation; Electric breakdown; Electrodes; History; Plasma properties; Surface discharges; Vacuum breakdown; Voltage;