Full-waveform measuring system for lightning current caused by lightning strikes to tall structures
Author
Cheng, Gao ; Lihua, Shi ; Bin, Chen ; Gongcheng, Zhang ; Bihua, Zhou ; Ziming, Chen
Author_Institution
Eng. Inst. of Nanjing, China
fYear
2000
fDate
2000
Firstpage
340
Lastpage
343
Abstract
In order to protect electronic devices against the effects of lightning strikes to tall structures, detailed information about the lightning currents are necessary. For this purpose, a full-waveform measuring system was set up on the north towers of Jiangyin Highway Bridge. In this paper, the calibration to this system is introduced and the results of simulating lightning currents are given
Keywords
calibration; computerised instrumentation; data acquisition; electric current measurement; electric sensing devices; lightning; optical cables; Jiangyin Highway Bridge; calibration; electronic devices protection; full-waveform measuring system; lightning current; lightning current measurement; lightning currents simulation; lightning strikes; tall structures; Bridges; Current measurement; Data acquisition; Electromagnetic measurements; Lightning; Magnetic field measurement; Optical fiber sensors; Oscilloscopes; Poles and towers; Semiconductor device measurement;