Abstract :
An indirect comparison between the 10 V Josephson array voltage standards of the BNM/LCIE and the BIPM has been carried out using Zener-diode based voltage references as transfer standards. The results show an agreement of 5 parts in 10/sup 9/ with an uncertainty (1/spl sigma/) of 3 parts in 10/sup 9/, mainly due to instability of the Zener references. A direct comparison is to be carried out early in 1994 to avoid this limitation.<>
Keywords :
Zener diodes; measurement standards; superconducting junction devices; voltage measurement; 10 V; 1994; BIPM; BNM/LCIE; Josephson array voltage standards; Zener-diode; instability; transfer standards; uncertainty; voltage references; Battery charge measurement; Calibration; Detectors; Dielectric losses; Dielectric measurements; Josephson junctions; Laboratories; Sensor arrays; Uncertainty; Voltage;