DocumentCode
2188971
Title
Line termination net for load overvoltage cancellation in medium to high power three-phase PWM VSI induction motor drives
Author
Fratta, A. ; Pellegrino, G.M. ; Scapino, F. ; Villata, F.
Author_Institution
Dept. of Electr. Eng., Politecnico di Torino, Italy
Volume
2
fYear
2000
fDate
19-22 Jan. 2000
Firstpage
261
Abstract
A line termination net (LTN) suitable for overvoltage cancellation in PWM VSI induction motor (IM) drives is investigated, deriving reliable LTN sizing design criteria in the medium-to-high power range. Such an LTN concept has been successfully tested for small power IM drives, by defining analytical criteria which are of general validity. These ones here are applied to medium-to-high power drives accounting for the LTN power loss terms which are negligible in small power drives. The effectiveness of the proposed power loss terms model is experimentally tested on a reference 55 kW IM.
Keywords
DC-AC power convertors; PWM invertors; induction motor drives; load (electric); losses; machine protection; machine testing; machine theory; overvoltage; 55 kW; LTN sizing design criteria; analytical criteria; line termination net; load overvoltage cancellation; medium-to-high power range; power loss terms model; three-phase PWM VSI induction motor drives; AC motors; Commutation; Frequency; Insulated gate bipolar transistors; Power cables; Power system modeling; Power transmission lines; Pulse width modulation; Testing; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Technology 2000. Proceedings of IEEE International Conference on
Print_ISBN
0-7803-5812-0
Type
conf
DOI
10.1109/ICIT.2000.854147