DocumentCode
2189995
Title
Ultrasound velocity to measure beef, chicken and fish fillet fat content
Author
Abdul Halim, M.H. ; Buniyamin, Norlida ; Mohd Shari, M.A. ; Abu Kassim, Rosni
Author_Institution
Fac. of Electr. Eng., Univ. Teknol. Mara, Shah Alam, Malaysia
fYear
2012
fDate
5-6 Dec. 2012
Firstpage
54
Lastpage
58
Abstract
The objective of this research is to develop a reliable non invasive method to measure fat content in beef and fish fillet using ultrasound A-Mode scan. The results of the fat measurement from this non invasive method were then compared to the results of fat measurement using a proven method. The Soxhlet method is a standard fat measurement procedure recommended by the Association of Official Analytical Chemist (AOAC). The samples used in this investigation are chicken, meat and fish fillets. The experimental results showed that there is correlation between fat content and the measured ultrasound velocity travelled in the sample. This indicates that fat measurement using the ultrasound A-Mode scan technique can be used to determine fat content in fillet with reasonable accuracy.
Keywords
chemical analysis; fats; food safety; ultrasonic materials testing; AOAC; Association of Official Analytical Chemist; Soxhlet method; beef fillet fat content measurement; chicken fillet fat content measurement; fish fillet fat content measurement; noninvasive method; standard fat measurement procedure; ultrasound A-Mode scan; ultrasound A-Mode scan technique; ultrasound velocity; A-mode scan; Fat content; Fillet; Ultrasound velocity;
fLanguage
English
Publisher
ieee
Conference_Titel
Research and Development (SCOReD), 2012 IEEE Student Conference on
Conference_Location
Pulau Pinang
Print_ISBN
978-1-4673-5158-4
Type
conf
DOI
10.1109/SCOReD.2012.6518610