DocumentCode
2200513
Title
Comparison of radiated immunity tests in different EMC test facilities
Author
Streitwolf, Holger ; Heinrich, Ralf ; Behnke, Heinz-Günther ; Dallwitz, Lothar ; Karsten, Uwe
Author_Institution
Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin, Deutschland
fYear
2007
fDate
24-28 Sept. 2007
Firstpage
229
Lastpage
232
Abstract
This paper reports about investigations of different EMC test facilities from immunity point of view. A special test device has been developed in order to obtain a quantitative measure for the immunity test. Using this test device different test facilities are compared regarding their repeatability and reproducibility as well as other advantages and drawbacks.
Keywords
Anechoic chambers; Battery charge measurement; Distortion measurement; Electromagnetic compatibility; IEC standards; Immunity testing; Radio frequency; Reproducibility of results; Reverberation chamber; Test facilities;