• DocumentCode
    2200513
  • Title

    Comparison of radiated immunity tests in different EMC test facilities

  • Author

    Streitwolf, Holger ; Heinrich, Ralf ; Behnke, Heinz-Günther ; Dallwitz, Lothar ; Karsten, Uwe

  • Author_Institution
    Physikalisch-Technische Bundesanstalt, Abbestr. 2-12, 10587 Berlin, Deutschland
  • fYear
    2007
  • fDate
    24-28 Sept. 2007
  • Firstpage
    229
  • Lastpage
    232
  • Abstract
    This paper reports about investigations of different EMC test facilities from immunity point of view. A special test device has been developed in order to obtain a quantitative measure for the immunity test. Using this test device different test facilities are compared regarding their repeatability and reproducibility as well as other advantages and drawbacks.
  • Keywords
    Anechoic chambers; Battery charge measurement; Distortion measurement; Electromagnetic compatibility; IEC standards; Immunity testing; Radio frequency; Reproducibility of results; Reverberation chamber; Test facilities;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2007. EMC Zurich 2007. 18th International Zurich Symposium on
  • Conference_Location
    Munich, Germany
  • Print_ISBN
    978-3-9523286-1-3
  • Electronic_ISBN
    978-3-9523286-0-6
  • Type

    conf

  • DOI
    10.1109/EMCZUR.2007.4388237
  • Filename
    4388237