2232933
Title :
Computation of “worst-case” bioeffects indices and pulse-average intensity values based on acoustic output data submitted to the FDA
Author :
Harris, Gerald R.
Author_Institution :
Center for Devices & Radiol. Health, Food & Drink Admin., Rockville, MD
fYear :
1993
fDate :
31 Oct-3 Nov 1993
Firstpage :
935
Abstract :
The authors recently have concluded an analysis of diagnostic ultrasound acoustic output data processed by the FDA during 1990 and 1991. As part of this analysis, “worstcase” models for transabdominal fetal exposures (assuming a “fixed-path” derating factor with an attenuation coefficient of 1 dB/MHz) have been used to calculate estimates of maximum temperature elevations and mechanical indices, and the results have been compared to corresponding calculations of the mechanical (MI), soft tissue thermal (TIS), and bone thermal (TIB) indices defined in the “Standard for Real-Time Display of Thermal and Mechanical Acoustic Output Indices on Diagnostic Ultrasound Equipment.” In this standard an attenuation coefficient of 0.3 dB/cm-MHz is used. In ≈75% of the approximately 100 cases examined, the TIB was within a factor of two of the corresponding worst-case value (i.e., worst-case value <2·TIB, and in over 95% of the cases the TIS and MI were within a factor of two of the corresponding worst-case values. In addition, maximum values of the derated spatial-peak, pulse-average intensity (ISPPA.3) have been computed assuming that the FDA regulatory output limit was based on an MI of 1.9 rather than an ISPPA.3 of 190 W/cm2. Under this condition, and assuming that pulse shape would remain constant as pulse amplitude is increased, ISPPA.3 values of up to 2300 W/cm2 were calculated
Keywords :
biological effects of acoustic radiation; biomedical equipment; biomedical ultrasonics; safety; ultrasonic effects; US FDA; acoustic output data; bioeffects indices; bone thermal indices; diagnostic ultrasound; mechanical indices; pulse amplitude; pulse shape; pulse-average intensity values; soft tissue thermal indices; transabdominal fetal exposures; Acoustic devices; Acoustic pulses; Attenuation; Displays; Drugs; Pulse shaping methods; Shape; Temperature; Thermal factors; Ultrasonic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 1993. Proceedings., IEEE 1993
Conference_Location :
Baltimore, MD
Print_ISBN :
0-7803-2012-3
Type :
conf
DOI :
10.1109/ULTSYM.1993.339654
Filename :
339654
Link To Document :
بازگشت